Research and design for multi-channel injection pumps
Syringes come in various sizes ranging from 250 µ L to 10mL
There are multiple materials and styles to choose from
Suitable for analysis, biotechnology, and diagnostic applications
Inquiry

Specification

Physics

Chemical aspects

Environmental aspects

Length 107.5mm (60mm stroke) Wetting materials, borosilicate glass, PCTFE, PTFE (or UHMW-PE)
Operating temperature: 50°F to 104°F (10°C to 40°C)
Length: 64.5mm (30mm stroke) Instructions for using the syringe
Storage temperature: 13°F to 185°F (-25℃ to 85℃)
Thread type
Laboratory-grade silicone lubricant
The relative humidity is as high as 100%


structural specifications:

Specification Model

itinerary

capacity

inner diameter size

outer diameter dimension

glass tube material

Piston material

Joint specifications

Suction and discharge accuracy

DC-X25061 60 25ml 23.04mm 27.2mm high borosilicate
UHMWPE 1/4-28UNF 0.5%
DC-X00061
60 10ml 14.56mm 18mm high borosilicate
UHMWPE
1/4-28UNF
0.5%
DC-500031
30 5ml 14.56mm 18mm high borosilicate
UHMWPE
1/4-28UNF
0.5%
DC-500061
60 5ml 10.3mm 13.8mm high borosilicate
UHMWPE
1/4-28UNF
0.5%
DC-100061
60 1ml 4.6mm 8mm high borosilicate
UHMWPE
1/4-28UNF
0.5%
DC-100031
30 1ml 6.51mm 10.2mm high borosilicate
UHMWPE
1/4-28UNF
0.5%
DC-250031
30 2.5ml 10.3mm 13.8 high borosilicate
UHMWPE
1/4-28UNF
0.5%
DC-250061
60 2.5ml 7.286mm 11mm high borosilicate
UHMWPE
1/4-28UNF
0.5%
DC-050031
30 500ul 4.6mm 8mm high borosilicate
UHMWPE
1/4-28UNF
0.5%
DC-050061
60 500ul 3.26mm 8mm high borosilicate
UHMWPE
1/4-28UNF
0.5%
DC-025031
30 250ul 3.26mm 8mm high borosilicate
UHMWPE
1/4-28UNF
0.5%
DC-025061
60 250ul 2.30 8mm high borosilicate
UHMWPE
1/4-28UNF
0.5%


Cleaning and maintenance: 

1. Do not use the syringe in a dry condition. 

2. After use, thoroughly rinse the syringe with purified water.

3. If the plunger moves with difficulty inside the syringe barrel, remove the plunger head, apply purified water on the seal, or apply silicone oil on the black seal, then reinstall the plunger head. If the plunger is removed from the syringe barrel, wipe it with alcohol before replacement. 

4. Replace the syringe seal regularly to ensure optimal performance. The frequency will depend on the usage frequency, the liquid flowing through the system, the syringe size, and the maintenance condition of the instrument


*

*

*

*

*